What do you need to pay attention to when the CNC router machine connecting the ground wire

The ground wire must be familiar with everyone. During the use of the CNC router machine, we need to pay attention to the safety hazards during the ground wire. We must meet the requirements and standards when operating CNC router machine. Safety. Therefore, you must pay attention to the following issues when connecting the ground wire of CNC router machine.

Installation and disassembly of the CNC router machine

When the grounding wire, we must first connect the ground clip and then connect to the electric clip; when removing the ground wire, we must first disassemble the electric clip in order and then remove the ground clip.

Divide the ground soft copper wire to the upper -eye copper nose on the ground clip (the electric clamp with a fixed and active) corresponding position on the ground rod, fix the single -eye copper nose on the ground line on the ground clip or On the ground needle, it constitutes a complete set of ground wires.

Check whether the voltage level of the ground rod is consistent with the voltage level of the operating equipment.

The ground soft copper wire has a division and combination, and the ground rod has a flat mouth and a double spring hook wire clip.

You must check the ground wire of CNC router machine before work

Whether the soft copper wire is broken, the screw connection is loose or not, whether the elasticity of the line hook is normal, and it should be replaced or repaired in time if it does not meet the requirements.

What is prepared to connect the ground wire of CNC router machine.

1. It must be checked first. The ground wire is more commonly habitual if the electrical line is not checked. The ground conductor cannot be in contact with the body.

2. Check whether the voltage level of the ground rod is consistent with the voltage level of the operation equipment.

3. Hanging ground wires at both ends of the work place to avoid the possibility of electric shock.

Precautions for use and maintenance during the ground wire connection.

1. When grounding piles, the ground physical fitness can quickly unlock the large current of the accident to ensure the quality of the ground.

2. The ground wire should not be distorted during use. When not in use, the soft copper wire should be well disk. After the grounding line is removed, it is not allowed to be dropped from the air or falling around. It should be passed with a rope to pay attention to the cleaning work of the ground wire.

3. Select the corresponding ground line according to different voltage levels.

4. It is strictly forbidden to use other metal line instead of ground wires.